LOD2 laser detector in furnace
Product application
Operating principle
The laser detector in the furnace (LOD2) is composed of a transmitter and a receiver. The transmitter on one side of the furnace emits a high-intensity infrared laser beam, which passes through the detection position in the furnace and is received by the receiver on the other side of the furnace. After processing by the photoelectric element, the control signal is output.
Feature
Visible red laser, easy to install and commission.
With water cooling device, it can work continuously in high temperature environment.
Technical parameters
power supply:DC24V or AC220V
Power supply: Red indicator
Detection distance: 50m
Minimum detection object: opaque object above Φ30mm
Ambient temperature: -25℃~55℃, adding water cooling can reach 130℃
Response time: relay 20ms; Voltage, electrical contact 2mss
Type explanation